[wanted] Unifi G3 Flex Cameras on Unifi VIDEO firmware
Warwick_Tech replied to Warwick_Tech's topic in Classified Adverts
At the moment I'm unsure, we're waiting on a shipment from the factory, but they can't guarantee what version firmware as they're likely to have come from Unifi direct - Thought it best to hedge my bets as the G4's didn't work out the box and we needed Protect -
[wanted] Unifi G3 Flex Cameras on Unifi VIDEO firmware
Warwick_Tech posted a topic in Classified Adverts
Hi All, Would anyone be interested in swapping for x3 G3 Flex cameras that are still on low enough firmware to support the old Unifi Video App? The new protect app is not designed for what we need and still need to run an old NVR so we can live feed to an iPad in another location. Happy to trade items or organise payment. Regards, -
Hidden Recycle bin on users area on file server?
Warwick_Tech replied to Jaan's topic in Learning Network Manager
Adding a useful CMD prompt I found for deleting Temp files and Thumbs.db D:\mydir being your home areas -
Windows Update Server - Windows Server 2016
Warwick_Tech replied to MattMerry's topic in Windows Server 2016
Might be obvious, but make sure you're using the correct version of Windows in the product categories - It can be confusing as 1909 uses 1903 updates and 20 onwards uses 'Vibranium' or some such codeword -
WSUS - Help and assistance; crashing after a week or so
Warwick_Tech replied to Warwick_Tech's topic in Windows Server 2019
So, It seems to be a firewall issue (typical) I'll do more research onto what I need to allow/disallow -
Hey All, I have a persistent problem with my WSUS server - She's a new build 2-3 years ago on Server 2019 x64, plenty of resources, RAM etc on a VM She's been working fine for years, but now suddenly she keeps falling over and the only solution is a restore from backup, but then a week later she falls back over again. Symptoms are: * WSUS service halts unexpectedly, will resart manually but makes no difference * Clients report generic error "There were some problems installing updates, but we'll try again later. If you keep seeing this and want to search the web or contact support for information, this may help: (0x8024401f)" * Tons of ASP.NET 4.0 errors in the log file * WSUS Error 507 - Update Services failed its initialization and stopped. * WSUS Error 7053 * MMC Errors * Lots of Events in Security Auditing 5152 ^ theres tons of these for all different ports and IP addresses --------------- Solutions: * Restore VM, but it then falls back over a week or so later * Increasing memory for IIS makes no difference * Increasing resources for VM, no change * Restarting all services, no change Anyone got any ideas? And no, I'm not moving to SCCM
-
Yes, I upped it to 99, still with a 30 minute timeout - the weird part is I'm getting a red error box 'invalid fields in SIMS.ini invalid fields in SIMS.ini' (Yes it says it twice!) I've tried the old 'save and send to clients trick' but they are definately communicating Also, sorry to hijack the thread! EDIT: Ok, so - Reinstalled the agent from the MSI too (why not right) and restarted the services several times it's finally installing .50 So after this is done, V.59
-
Thanks Both, that has brought her back to life and she is slowly (very slowly) updating Solus agents (I think) but the update is still stuck on 'Upgrade Service' in 'install mode' and any new agents are stuck in 'Install queued'
-
My Solus install has broken completely after an attempt to upgrade to .59 We had to go to .50 first but this removed the service, causing the update to freeze - So now I'm stuck with a brick. At least people can still use SIMS and our support company all working from home are 24hrs with no response....
-
Let's see what we have on our list; 60 new CCTV cameras (we've started the wiring and set up the NVR/DHCP addresses 90 new classroom desktops, which means 90 teacher machines moved to students, which means 90 scrap PC's to be disposed of Repairing and installing new cabinets after the roof burst over a cabinet (fun right) Getting ready for our new staff (IE moving everything 2 feet to the left) One thing that I'm not looking forward to is installing an exterior Unifi to a second floor emergency stairwell... If I'm not around in September you know why So the usual I suppose Oh, and how could I forget 20H2 - Though I have made no progress on the Wim and am tempted to see if it will be the last version of W10 to avoid future version upgrades, then wait 6 months to a year for W11
-
MDT Where are the answers to the Windows PE questions stored?
Warwick_Tech replied to Caffeine11's topic in O/S Deployment
I always wondered this one; as the PW is stored in plain text (presumably) what is the minimum rights an account needs to join PC's to the domain? I believe accessing the network shares UN/PW on launch and task sequence permissions are all encrypted, but things like the local admin and this PW are still in plain text - What rights has everyone got for this user? -
Maybe check in AzureAd to make sure the server is de-activated/disconnected/deleted, it can pop up in several places portal.azure.com > Azure Active Directory > Devices Or on windows: Settings > Accounts > Access to Work or School > disconnect any accounts there Or - It still thinks an install is pending/in progress - I *THINK* you restart or force close the installer service, but I could be wrong on that one
-
Partition Woes - Recovery and Extend, third party?
Warwick_Tech replied to Warwick_Tech's topic in Windows Server 2019
Well, it seems to be ok - Though that article is in need of some translation and error correction - Basically it turns out they were using the newer recovery partition, as I assigned two drive letters (R and T) and it reported T was the primary recovery partition; Though when I ran reagentc /disable it deleted the .wim file completely (both times) so had to steal it from another server and re-register them the annoying part was I couldn't use the old recovery partition as it was 5mb too small and creating a new one would just drop it at the back, blocking future expansion without going through this whole process again So workaround was to load the recovery partition onto C: directly (not ideal, but it's all on the same physical drive anyway) and make sure it was pointed to C: In conclusion, it's actually interesting to see how all this works and I would encourage doing the first few steps to check your partition tables, though do not run reagentc /disable without due course and attention! -
Hi All, So I decided to give my VM's some more space to work with, but although extending the drives worked for the newer one, older units that had two or more recovery partitions won't extend because they cannot access the block of data behind the Recovery Partition - I've been recomended third party apps like AOMEI, but the free version has now server support (apparently) Can anyone share some insight? Also noticed my two virtual hosts have no recovery partitions at all (?!) EDIT: This is looking promising Extend Volume Blocked by a Recovery Partition on Windows 10 | Windows OS Hub
-
Hi All, So we recently delved into; Azure AD > Devices And discovered all our domain devices and all our Covid laptops loaned out as well as a bunch of personal machines. Now, as is my understanding this is when they add their account to office/windows 10 etc. etc. either at setup or 'connect my work or school account' They are limited to 20 devices currently, but realistically how do you control this? I would've thought domain machines and personal devices should be kept seperate, but how (?) It's a bit of a mess of settings. We also have some guest users who appear occasionally - We delete them and make sure the settings are up to date but occasionally they sneak in, what could we be missing? Azure AD > Users > Add filter > User Type (Guest) Who are these guys?
-
http://www.edugeek.net/forums/classified-adverts/222783-no-idea-if-useful-anyone-if-its-worth-anything.html#post1908380
-
[wanted] Comms Cabinet (Medium/Large) - Floor Standing?
Warwick_Tech posted a topic in Classified Adverts
Hi all, Long shot, but does anyone have a medium/large floor standing or wall mounted rack going spare? Condition doesn't matter, but ideally with locks/replaceable locks This needs to fit a Unifi POE switch (chunky boys) and a new NVR PRO 442 x 325 x 87 mm (17.4 x 12.8 x 3.4") 442.4 x 399.6 x 43.7 mm (17.42 x 15.73 x 1.72") Can be any size, but ideally half height or smaller (6-12U) ----- Happy to trade some kit, potentially Server (no HDD's) or Projectors etc. or beefy core switch (HP I think?) -
Remember in Attribute Editor (ProxyAddresses) it takes any in caps SMTP as primary and lowercase smtp as secondary https://techcommunity.microsoft.com/t5/exchange-team-blog/admodify-net-is-here/ba-p/610119 ADModify should allow you to change on-premises then sync using AAD - Use the wildcard %username%@
-
The only issue we have is people on holiday, or when using privately paid for VPNs (Nord for example) the argument is why would you need emails while on holiday, however for things like safeguarding that always seems to be the trump card We compromised with MFA and geoblocking for confirmed breach locations.
-
I have very little optimism anyone who works at MS R&D knows what Group Policy is these days, I blame millienials....
-
Given MS poor past experiences of 'trying something new and exciting' I would be inclined to agree - It's highly unlikley this version of Windows will have anything significant changed under the hood, all modern versions of Windows are simply MS-DOS with sparkly bits. I still get funny looks when I go to 'old' windows boxes instead of the shiny UI - It will be a long time before we are rid of DOS! C:\DOS C:\DOS RUN RUN DOS RUN
-
Maybe try 'Dynamic' - as a test I switched mine to 'Switch Independent' and got some errors - Although as I write this, it's gone green... --------------- Old config for reference: I've also found sometimes better cables don't always equal better results, try a standard Cat5e or Cat6 cable