Posts
9,220 -
Joined
-
Last visited
Content Type
Forums
News
20th
EduGeek EDIT Conference
Blogs
Everything posted by Andrew_C
-
Gatwick Flights Suspended Again After Suspected Drone Sighting
Andrew_C replied to 6Foot2's topic in General Chat
only ever be used for locking up a peaceful protestor that has got under the skin of the govt. -
They ALL used to do just this. A compound by the tills full of boxes; I guess it doesn't look 'corporate' enough.
-
Yes, but... You pop, unplanned, into the shop on the way home without your bags; what are you going to do? Juggle a bag of spuds, 3 lemons and a fruitcake all the way home?
-
It was a Stark album.
-
Fairie was an early one for me, but then the setter and I seem to like one particular band.
-
Yeti? I only see a monster.
-
Aside from what's gone before:- Techlab Ltd - not used them, but have been recommended. Harding Scientific Instruments Ltd - Home - used them, slow and not cheap.
-
Up to 44. Some are bizarrely simple, others quite convoluted. Some songs I've never heard of!
-
I bank with Lloyds. Full AA cover, travel insurance, phone insurance, and other stuff, all for £17 a month.
-
ifour have a new Christmas music quiz. https://quiz.ifour.co.uk
-
Unless you aren't chalky white, in which case you get sent to Guantanamo as a "terrorist" for the same actions.
-
I've just bought four of their tablets; just before this all blew up. OK, not national security level, but still...
-
Head Teacher fined for DP breach
Andrew_C replied to rom1984's topic in Data Protection & Information Handling
A little O/T, but does anyone have a link to a teacher or school getting a kicking for loosing data via lost device or stick? -
-
What power provisions do you have for your server racks?
Andrew_C replied to talksr's topic in Learning Network Manager
There's that too, but it ain't going to kill you! -
What power provisions do you have for your server racks?
Andrew_C replied to talksr's topic in Learning Network Manager
OK, back from the dentists' waiting room... There are several possible earthing arrangements for buildings. Some, as you say have a single earth point , but a common arrangement is PME - "protective multiple earth" whereby all metal services are connected together, and to neutral somewhere near the building. At the other extreme there is TT which relies solely on the mass of the earth for the return to the generating station. In fact, the regs have a whole chapter on this stuff that I've not looked at for 25 years. Now, for the wiring of earth within the building:- Most people (I hope) understand that the earth connection is there to allow a sufficient current to flow in the event of a fault to cause the protective device to clear in a timely fashion. This includes RCDs, MCBs and old fashioned fuses. The time is up to 1/2 second for a fuse. The second less well understood function is to ensure that you don't get a life threatening shock if you happen to be touching something metal with one hand, and a faulty appliance with the other. Imagine if you will pushing down the toaster lever and touching the metal case as a fault develops. Your other hand is on the tap. You die... With earth bonding, the case of the toaster is connected to a wire back to earth in the system, this in turn is connected to the water pipes. Thus as the case rises up to 230V, so does the water pipe. There is then no potential across your body. You live... This is referred to as "Equipotential Earth Bonding" and is why there's lots of green & yellow wire linking pipes together under sinks and similar locations. -
What power provisions do you have for your server racks?
Andrew_C replied to talksr's topic in Learning Network Manager
Oh, and depending on your earthing arrangements, you are wrong with your one point of earth. -
What power provisions do you have for your server racks?
Andrew_C replied to talksr's topic in Learning Network Manager
'all extraneous metal work liable to be energised in the event of a fault shall be bonded together' In this case the metal rack must be bonded to all the other metal in the building. Pipes, frame etc. You cannot use a plug and socket in this case. I know lots do, but you shouldn't. -
What power provisions do you have for your server racks?
Andrew_C replied to talksr's topic in Learning Network Manager
Please be aware that the racks should have a permanent earth connection, and not rely solely on the connector. This is due to the earth of your server room being exported to other locations. Unless adequately bonded, a fault in this other location could raise to local earth potential - and this is dangerous. -