We are experiencing an intermittent fault with Windows 10 clients group policy printer settings. Clients receive printer mappings via Computer Group Policy Preferences, these all apply correctly. Clients will sporadically drop printer connections; this occurs after users have been logged on for a period of time. When checking Devices and Printers the printer is not showing, however the printer still shows within applications when going File | Print, Device Manager shows no printer installed, trying to reinstall the printer manually will give a generic Windows 0x0 error. No policy processing errors are appearing on the local client in event Viewer. Carrying out a reboot will remap the printer and gpresult /r shows the policy applying correctly. We have also tried disabling background updating of printer policies to no avail. All clients are Windows 10 LTSB. Any thoughts? Thanks Paul
-
Please see attached advert, any questions feel free to PM me. Vacancies - Stonyhurst College Networking Engineer.pdf
-
Network Engineer - Clitheroe, Lancashire -Closes 23/10/15
paul posted a topic in Educational IT Jobs
We are looking to expand our current Technical Support Team, please see here for details. -
Think you may be in for a long wait, wasn't it about May last year...
-
@buzzard unfortunately its not quite as simple as that, for a start there is the decommissioning of the DSLAM for those particular circuits within the exchange. On top of this there is the termination/removal of additional services schools have as part of there CLEO subscriptions e.g. Moodle.
- 21 replies
-
Unfortunately no
-
To place two lessons on at the same time with the same class teacher requires a clash to be locked into the scheduling. This can be done either on the Block screen or the Band screen, in the screen shot below I have already scheduled 12D/Ar1 onto Tue1, now on the Year 11 Option A block drag the session onto the timetable screen: Tue1 is highlighted in green as there is currently one clash, in this case the art class, upon releaseing the cursor over Tue1 the following screen will appear: Tick the Lock/Clash column and click OK The session on the build screen will now display in green denoting that the session is locked, removing the lock will remove the scheduling from the session. The staff members Timetable will now show both classes.
-
[sims] Urgent Help needed.. Can't logon to sims.net
paul replied to swiftysw1's topic in MIS Systems
Backup will be located in the backups directory within the default SQL Server application location on the server (usually D:\Program Files\Microsoft SQL Server\MSSQL10.SIMS2008\MSSQL\Backup), you will need to run dbattach.exe from on the server to restore. -
More info regarding licensed handportables and costs on this thread: http://www.edugeek.net/forums/general-chat/100600-2-way-radio-suggestions.html
-
We have a number of schools who have similar arrangements, this is what we would normally recommend: The best way to deal with this would be to change your reg organisation to AM lessons, you would then timetable the reg periods as actual lessons on the Mon, Tue, Thu, & Fri. Reg would now in essence be period 1. For the Wednesday session mapping would point to period 2 and you would set P1 on a Wednesday as a dummy period. Earliest marks would apply to every day unless you switched on and off prior to the start/end of the day, consequently not recommended (this is aimed at post 16 use only).
-
I have sent you a PM
-
[sims] SIMS AD intergration - Put a password in a second time?
paul replied to FN-GM's topic in MIS Systems
Editing the connect.ini file to the following will require user to enter AD password again [sIMSConnection] ServerName=[servername]\[DB Instance] DatabaseName=SIMS Commandtimeout=100000 ConnectionType=Trusted