Hi Fiza,
Did you have any trouble adopting the switch to the controller?
I'm setting up a small scale test network and we have a US-48, a US-48-500, 2 AP-AC-PRO and 1 cloud key for the controller.
When I plug the 48 port POE switch in, and the cloud key into that, I can get into the fallback IP for the controller (192.168.1.30) and configure it, but I change the IP to something on our management IP range (lets say 10.20.30.10).
When logged in after the setup wizard, I can see the 48-500 switch pending adoption on a default IP 192.168.1.20 but as the controller IP is now on a different subnet it will not adopt.
If I adopt the switch before changing the controller's IP so they both have a 192.168.1.x address then the switch adopts fine. I then try changing the switch IP address to 10.20.30.11, change the controller to 10.20.30.10 again and although they are both on the same subnet now, the controller loses connection to the switch...
Did you have any trouble like this?
Thanks,
L