I have a server in which one of the dives has failed and needs swapping out. The raid card is an LSI MegaRaid SAS 9260-8i. Available storage shows as 1.63TB with four 600GB disks so I assume it’s raid 5. I’ve never had to do this before and searching the web has not helped. When the drive is swapped out will the new drive just start rebuilding or will it have to be configured. The server is ESXi so anything would have to be done in the webbios. If changes have to be made could someone point me to a step by step guide. Thanks.
-
Have a look at section 6.1 of this Microsoft memorandum of Understanding. They clearly do not need to be included. I've only just found this document. I will be looking at my schools FTE count next OVS-ES renewal as quite a number of TA's that I've previously counted should not have been.
-
Sorry, I missed that.
-
A new screen should cost you just shy of £40 delivered for that model. Get the make and model number from the back of the screen and call someone like Accupart.
-
Is there some secret knack to installing USB connected HP printers using the Universal print drivers? I always struggle unduly but now have one that is identified immediately as an unknown USB device and no amount of uninstalling and reinstalling seems to change that. This is on Windows 7 32bit.
-
Moving Junior Librarian .net to new server
mrwobbly replied to Jobos's topic in Educational Software
I take it you have looked at Article No. 1806 on the Microlib support site which lists the error and fix. -
Have you tried this? How to Reset a NEC Projector Lamp Timer - Projector Lamp Services
- 1 reply
-
- lamp timer
- nec mt1030
-
(and 1 more)
Tagged with:
-
This worked for me. Remember you need to reboot before font is visible. SOLVED: How To Deploy Fonts Using Group Policy - Up & Running Technologies Calgary
-
Just to follow up, if the normal speed was 7Mb and you are now seeing 3.5Mb plug your router into the BT master socket. Take the two screws out of the master socket and remove the bottom faceplate. Plug the router in to the test socket you can now see and test from that. Try a second filter if speeds are still slow. If you still have a problem at the BT test socket get your phone provider to do a line test. Line noise due to bad joints is most likely cause here. If the BT test socket test is ok look at getting a BT I-Plate, ADSL master socket or just go round and remove all the ring wires from all sockets.
-
Your girlfriend is on an ADSL 2 enabled exchange which would deliver up to 24Mb. ADSL2 speeds fall off quite rapidly as distance from the exchange increases. Only some exchanges were upgraded to ADSL2. You could be on a different exchange which was not enabled and are receiving near the top end speed possible for ADSL1 being close to the exchange with 7Mb. You can both have the same area code, be near to each other but on different exchanges. Do an exchange search here https://www.samknows.com/broadband/
-
You have the Microsoft NET security fix KB3142026 on your build server. Remove it and you should be ok.
-
Is it still possible to download Ac 1.7? I have 30 iPads and a Mac Mini to set up this week and it doesn't sound like Ac2 is worth the heartache at the moment. Thanks Nick
- 413 replies
-
- apple
- configurator
-
(and 2 more)
Tagged with:
-
Reboot vSphere host and install new tape drive.
mrwobbly replied to mrwobbly's topic in Thin Client and Virtual Machines
Just a little bump. -
I’m new to vSphere and need to fit a replacement tape drive to a vSphere host. Should I RDP into each virtual server and shut them down or put them in maintenance mode and shut them down from the vSphere client. Then put the host into maintenance mode and reboot it? What are the steps then to get the new drive recognised in the virtual server hosting Backup Exec. Thanks