Hi,
I have had to order two replacement 3Com 4200g 48port switches, due to them failing.
Both of them are connected via fiber connections, 1 is in Post Sixteen Center & one is in admin.
The one in Post sixteen center was set up with IP address and all swapped, fiber worked first time.
the admin one, the fiber ports will not work, its picked up an IP address and is connected to the network, as i have the old one still fiber-ed in the panel resting above the replacement, and all plugged in to the replacement works on the network and has a connection,
to get the fiber working, i have replaced the cable in the panel, replaced the fiber module, but still nothing. I used the same method as the post sixteen switch, same type of fiber cable from the fiber modules to the switch, same type of modules as was in the faulty one
Anyone got any clues, i would really appreciate any help ,as i'm at a dead end with what to try next? I contacted HP but they weren't much help at all.
Thanks
Angela