I have an interesting situation since I've put Meru 832e's in our high school. Whenever I reboot three or more - my entire network - goes down. If I reboot just one - I lose network connectivity district wide for probably ten seconds (our pings come back as unreachable) then normal network resumes. When rebooting three or more - maybe one ping in 20 get to their destination - if lucky.
When I say entire network - I mean it - wired, wireless - internal and external communications - all gone.
To "fix" this - in some cases I can just unplug the ethernet cable from the Meru 3200 controller, wait a few seconds and plug back in - usually network goes back to normal after fifteen to twenty seconds. In some cases I have to reboot the Meru controller. I can replicate this anytime by rebooting three AP's.
Anyone else ever have a similar experience? I am starting to believe it may be ARP poisoning.. we've run wireshark against the controllers swith port and don't seen any flooding going on, nor anything in the pcaps that jump out at us. Our network switch is Enterasys - just over a year old. The Ap's were installed this summer and I didn't reboot any AP's until last month when I was upgrading them and the controller.