  1. New 1.26 firmware released by HP. [ATTACH]31929[/ATTACH]
  2. factory reset your switch.
  3. CRC32: ca3c6ede MD5: a013fce576ca6f71c9e42153e723599d SHA1: adc28f2094c0072ac8afd42c4d53915286aa72a9 pk_1_21_1810_48G.zip
  4. The HP Tech got back to me with a link to the PK1.21 firmware. I have already updated my switches with kestrel1's firmware. The link at the bottom is the firmware downloaded from HP and re hosted. Please PM me if the link goes bad. This is the draft release notes that come with PK1.21. Version: PK.1.21 Status: Released and fully supported Release date: 7 January, 2014 ENHANCEMENTS This version does not contain enhancements. SOFTWARE FIXES This version contains the following fixes: • 0000128904 – Port Hang – Randomly, a port on the switch may hang. No MAC addresses will be registered on the port and both inbound and outbound traffic will no longer be forwarded on an affected port. The only recovery method is to reset the switch. • 0000140101 – SNMP – The software does not create an instance for a trunk for the the object ifInDiscards (.1.3.6.1.2.1.2.2.1.13). When the object is queried, the log may return the following message: UNKN Failed to get counter value. When requesting the trunk's instance of the object directly, the software returns the error No Such Instance currently exists at this OID • 0000142367 – SNTP – The switch may stop requesting SNTP updates after it received a Kiss-of-Death (KoD) packet with an INIT or STEP code. After it received such a packet, the switch should retransmit using an exponential backoff algorithm if no other NTP server is available, but instead, it stops requesting SNTP updates altogether. • 0000142692 – LLDP – The switch transmits incorrect LLDP MED TLVs that contain an incorrect VLAN ID, thus causing devices to be assigned to an incorrect or non-existing VLAN. The proper behavior for the switch is to not transmit LLDP MED packets. • 0000145820 – Jumbo Frames – When Jumbo Frames are transmitted over a trunked port, the software increments both the counters Transmitted Packets without Errors and Transmitted Packets with Errors. http://www.filedropper.com/pk121181048g pk_1_21_1810_48G.zip 3143376 bytes CRC32: 481622b2 MD5: db6efc059e6fca79c8c22ff548cad8db SHA1: 3c25aa46b283afa73971719a460383f423173de7
  5. Thanks kestrel1 for the firmware. I have updated my switches with PK1.21, I'll report back if there is any problems encountered. BTW SNTP does work with the PK1.21 firmware, you need to unselect SNTP, click apply and then reenable SNTP with the same settings.
  6. I seemed to still have the problem on a couple of switches after the firmware update but once I power cycled them at the wall socket they seemed come right.
  7. It seems that there is a new firmware that fixes this problem. https://h10145.www1.hp.com/Downloads/SoftwareReleases.aspx?ProductNumber=J9660A&lang=en,en&cc=us,us&prodSeriesId=3963985
×
×