Hi All
Im having a strange problem. Im running a network with around 200 computers running windows 7. My Domain Controller and DHCP Server are windows 2008 R2.
I have 5 computers suffering from the same problem. They have an IP Address from the DHCP server but they are unable to communicate with the rest of the next work. I am unable to ping the domain controller from these computers. Other computers are fine. This seemed to happen last Friday afternoon, before then they were all fine.
If I plug another computer into the same network socket as one of the problem PCs it works fine. If I take the problem PCs and plug them into another location on the network they start to work. Once I plug them back into the original network socket then the problem persists.
If I add an additional Network Card to the problem PCs disabling the Onboard one that fixes the problem. Also if I reformat the Hard Drives and Reinstall Windows that also fixes the problem.
My only clue to what is going on is when I pxe boot to my WDS server instead of getting an IP Address from the DHCP server I get an ARP Timeout error.
Any one have any ideas.
Many thanks for any help.
Tim