I don't have a high enough post count to PM yet:
Hi, I would be very interested in seeing your working package, we were able to package it on CC3 but not on CC4, the deployment just stop midway through.
I have a word document which covers a lot of this if you supply your email address, I'll forward it on. I'll provide a quick summary.
======================================================================================
Give the “everyone” group “full control” permissions over the following folders:
C:\Documents and Settings\All Users\Application Data\
C:\Program Files\Autodesk
Open the registry editor and give the “everyone” group “full control” permission of the following registry key:
HKEY_LOCAL_MACHINE\SOFTWARE\Autodesk
We also found the if the permissions aren't set before 1st run, WSE 3.0 has to be removed and installed again from the deployment image.
To get the Mechanical desktop to run we needed to add a lot of path and file fules and edit the MSI with ORCA to redirect the template to P:\
Allow
AcDeltree.exe(17.2.54.0)
%userprofile%\Local Settings\Temp\*.0001
%userprofile%\Local Settings\Temp\*.ac$
%userprofile%\Local Settings\Temp\*.log
%userprofile%\Local Settings\Temp\AdskCleanup0001.dir.0000\*.pfd
%userprofile%\Local Settings\Temp\AdskCleanup0001.dir.0000\*.tmp